Electrical Projects

Solar | All | Electrical

160 kW Solar PV System  BreadTop Factory Brisbane

160 kW Solar PV System
BreadTop Factory Brisbane

Installation of 160kW Solar PV System;
  • Annual Energy usage reduction of 318,000 kWh's per annum
  • Monitoring system for Peak Demand management
  • Return on Investment of 3.2 years
  • Included onsite maintenance program
50 kW Off Grid System

50 kW Off Grid System

Installation of 50 kW Solar PV System with integrated battery bank and diesel generator;
  • Diesel savings of $42,000 per annum
  • Battery back up for night usage and peak demand reduction
  • Monitoring system for Peak Demand management
  • Return on Investment of 2.2 years
  • Included onsite maintenance program
100 kW Solar PV/Diesel Hybrid System with Battery Back Up

100 kW Solar PV/Diesel Hybrid System with Battery Back Up

Installation of 100kW Solar PV with integrated battery bank and diesel generators;
  • Generator diesel and maintenance cost reduction of $79,000 per annum
  • Generator integration with SMA Fuel Save Controller
  • Click here for a short introduction video to the SMA Fuel Save Controller
  • Battery back up for night usage and peak demand reduction
  • Monitoring system for Peak Demand management
  • Return on Investment of 1.8 years
  • Included onsite maintenance program
110 Lot Subdivision  Currumbin Ridge Estate Gold Coast

110 Lot Subdivision
Currumbin Ridge Estate Gold Coast

Currumbin Ridge is a rare offering of luxury 'tree top' style homes located in a lush bush land setting with spectacular views overlooking the southern Gold Coast Region.

  • Complete design and construct for underground electrical and communications infrastructure including trenching, excavations, boring, foundations and conduit/pit installations
  • New Padmount transformer
  • Underground Electrical Reticulation
  • Telstra Pit & Pipe infrastructure
  • Main Site Switchboard and meter boxes for units throughout site
  • Public lighting and communal recreational areas
  • House wiring for all units
Transformer/Supply Upgrade  BreadTop Factory Brisbane

Transformer/Supply Upgrade
BreadTop Factory Brisbane

Installation of new 750kVA/1,200 Amp Ground mounted transformer including;
  • Excavation works & precast culverts
  • Retaining walls & concrete surround slabs
  • New cabling from Transformer to New Main Switchboard
  • Design & installation of Mains and switchboards throughout Site
3 Level / 9 Unit Complex  Kedron Brisbane

3 Level / 9 Unit Complex
Kedron Brisbane

Electrical & Mechanical Ventilation works for 9 units in a 3 level complex.

  • Electrical and communications infrastructure works
  • Main Site Switchboard and load centres for units
  • Public lighting and communal recreational areas
  • Internal wiring for all units
3 Level / 11 Unit Complex  Gaythorne Brisbane

3 Level / 11 Unit Complex
Gaythorne Brisbane

Electrical & Mechanical Ventilation works for 11 units in a 3 level complex.

  • Electrical and communications infrastructure works
  • Main Site Switchboard and load centres for units
  • Public lighting and communal recreational areas
  • Internal wiring for all units
ARC  Eagle Farm Brisbane

ARC
Eagle Farm Brisbane

Relocation works for ARC Reinforcing from Pinkenba to Eagle Farm including;

  • Installation of 450 metres of high level cable tray and cabling for 7 new switchboards
  • Installation of switchboards and sub circuits for equipment and machinery
  • Supply & installation of 1 x 350kVA & 1 x 250kVA diesel generators